Effectiveness analysis of external heating system of gauge tank of pumping unit using exhaust piping of the IC engine

Бесплатный доступ

Introduction. The heating efficiency or regulation of the operating temperature of the fluid located in the gauge tank of a mobile pumping unit (PU) using the exhaust system of the internal combustion engine (ICE) is studied. The paper objective is to improve the design process and to reduce costs of field experiments.Materials and Methods. To solve this problem, numerical analysis methods were used when calculating the heating systems of the gauge tank with the external location of the pipeline from the ICE exhaust system by the example of the widely used installations (TsA-320, UNB, AChF, etc.). Siemens STAR-CCM+, a non-stationary non-linear solver of gas-dynamic processes, was used, which evaluates the correctness of the problem statement and reduces significantly the costs of full-scale field tests.Research Results. The study was conducted for the operating conditions of the cementing unit on the Kamaz-43118 chassis with the SIN-32 pump and a drive from the power take-off attachment on the gearbox of the chassis engine...

Еще

Mobile pump unit, gauge tank, water feeding pump, high pressure pump, internal combustion engine (ice)

Короткий адрес: https://sciup.org/142219842

IDR: 142219842   |   DOI: 10.23947/1992-5980-2019-19-2-164-169

Статья научная