The study of the operation of the parodynamic thermosiphon and the thermosiphon without inner circulation loops
Автор: Shapovalov A.V., Rodin A.V., Vasiliyev L.L., Zhuravlev A.S.
Журнал: Агротехника и энергообеспечение @agrotech-orel
Рубрика: Энерго- и ресурсосбережение
Статья в выпуске: 4 (17), 2017 года.
Бесплатный доступ
The article presents the results of an experimental study of the performance of high-efficiency heat transfer closed two-phase devices - thermosyphons filled with distilled water and ethyl alcohol. A patented design of a steam-dynamic thermosiphon with annular channels in an evaporator and a condenser and a transferred transition zone is described. The experimental setup and the procedure for conducting the research, the conditions for conducting the experiments are described. A comparison is made between the intensity of the classical thermosyphon work of a cylindrical structure and the parodynamic thermosyphon with an internal circulation loop. A method for utilizing heat from compressor plants using recuperators based on two-phase thermosyphons is proposed. The external view of the recuperator using parodynamic thermosyphons as heat-conducting elements is shown. A system for cooling solar panels of photovoltaic installations is presented.
Thermosiphon, thermal resistance, recuperator, compressor, solar panel
Короткий адрес: https://sciup.org/14770216
IDR: 14770216