Clinical and angiography efficacy of the paclitaxel-coated balloon coronary angioplasty in patients with in-stent restenosis

Автор: Osiev A.G., Mironenko S.P., Krestyaninov O.V., Vereshagin M.A., Kretov E.I., Birukov A.V., Prokopenko R.N., Grankin D.S.

Журнал: Патология кровообращения и кардиохирургия @journal-meshalkin

Рубрика: Ишемическая болезнь сердца

Статья в выпуске: 4 т.14, 2010 года.

Бесплатный доступ

The present article shows the analysis of clinical and angiography efficacy of the paclitaxel-coated Balloon coronary angioplasty in patients with in-stent restenosis (ISR). In our study we included 90 endovascular interventions performed from 2008 to 2010 for the treatment of in-stent restenosis. The patients were classified into 2 equal groups based on an endovascular technique used. 35 patients (group I) were treated with a coronary balloon catheter coated with paclitaxel (SeQuent, BBraun; Dior, Eurocor).Patients from group II (n = 55) were revasculated with standard balloon angioplasty. Long-term outcome after angioplasty was assessed in 20 (57.2%) and 24 (43.6%) patients of the divided groups. The digital angiography was repeated within 6.4±0.11 months. Angiographic restenosis was revealed in 4 (20%) cases in group I and in 13 (54.2%) cases in group II. We revealed the decrease of angina pectoris middle functional class from 2.25±1.0 to 1.65±0.73 (p

Еще

Coated balloon catheter, paclitaxel, in-stent restenosis

Короткий адрес: https://sciup.org/142140364

IDR: 142140364

Статья научная