Electrical resistance preheating of high-amperage cells
Автор: Puzanov Ilya I., Zavadyak Andrey V., Tretiyakov Yaroslav A., Morozov Mikhail M., Gubin Anatoliy A., Platonov Vitaliy V., Darkin Aleksandr V.
Журнал: Журнал Сибирского федерального университета. Серия: Техника и технологии @technologies-sfu
Статья в выпуске: 5 т.7, 2014 года.
Бесплатный доступ
At present, there is no single opinion on which cell preheating method is best. In most cases, such a method (that is to be chosen for a smelter) is chosen based on a number of objective and subjective factors. It is often when a method is chosen that power expenses (either electricity or power generated from fuel combustion) for such a method are not taken into account. However, it can play a crucial role for different regions and influence the production cost of Al. This paper discusses the results of testing the method of electrical preheating in a pilot cell area (RA-400 cells) at OJSC RUSAL Sayanogorsk.
Ra-400 high-amperage cell, electrical preheating, technology development and technology management, experiment performance
Короткий адрес: https://sciup.org/146114873
IDR: 146114873