Injectional multilens molding parameters optimization
Автор: Kazanskiy Nikolay Lvovich, Stepanenko Ilya Sergeevich, Khaimovich Alexander Isaakovich, Kravchenko Sergey Vasilyevich, Byzov Egor Vladimirovich, Moiseev Mikhail Alexandrovich
Журнал: Компьютерная оптика @computer-optics
Рубрика: Дифракционная оптика, оптические технологии
Статья в выпуске: 2 т.40, 2016 года.
Бесплатный доступ
A technique for controlling and optimizing injection molding parameters by numerical simulation is proposed. Using this method for an optical element designed for roadway lighting, multilens molding quality criteria have been defined. Optimal parameters for lens manufacturing have been determined. Based on these parameters, a polycarbonate multilens has been made with an absolute tolerance equal to 0.01 mm.
Injection molding, optical element, intensity distribution, free-form surface, taguchi's method
Короткий адрес: https://sciup.org/14059455
IDR: 14059455 | DOI: 10.18287/2412-6179-2016-40-2-203-214