Operation of single-screw pumps with liquids of various viscosities

Бесплатный доступ

Changes in the operation of single-screw pumps when pumping liquids of different viscosities are considered. The dependences of the pump parameters 1B 1,6/5-1, 5/2 on the viscosity of the liquid are given. The efficiency coefficient was calculated from experimental feed and power values.

Single-screw pump, fluid viscosity, hydraulic losses

Короткий адрес: https://sciup.org/148319977

IDR: 148319977

Статья научная