A rare case of bladder catheterization complication in a patient with traumatic spinal cord disease
Автор: Khudiaev A.T., Prudnikova Оксана Германовна, Savin D.M.
Журнал: Гений ортопедии @geniy-ortopedii
Рубрика: Случай из практики
Статья в выпуске: 2, 2010 года.
Бесплатный доступ
The article deals with a rare complication developed during bladder catheterization with Foley permanent soft (rubber) catheter for sharp urine retention in the acute period of traumatic spinal cord disease. The difficulty of clinical diagnosis is caused by the disorder of conducting function of the spinal cord after its injury. Ureteral orifice occlusion occurred after the manipulation led to renal carbunculosis and required nephrectomy performance.
Blader catheterization, traumatic spinal cord disease, urinary tract infection, renal carbunculosis, nephrectomy
Короткий адрес: https://sciup.org/142121300