Correction of spatial losses in television registration system working in certain conditions

Бесплатный доступ

The special conditions related to the presence of radiation-protective observation system by thickness of several hundred millimeters between the object and lens camera, are making specifics in formation of the television image. The image on the surface of a matrix of the CCD is already broken chromatic and monochromatic aberrations of observation system, which leads to the emergence of spatial loss of information. The article discusses a method of correcting the spatial losses caused by monochromatic aberrations in observation system, are given the results of its practical implementation.

Radiation-protective observation system, discrete fourier transform, frequency domain, contrast transfer function