Surface laser microprofiling

Автор: Verkhogliad A.G., Stupak M.F., Chugui Yu. V.

Журнал: Сибирский аэрокосмический журнал @vestnik-sibsau

Рубрика: Технологические процессы и материалы

Статья в выпуске: 2 (28), 2010 года.

Бесплатный доступ

Brief description of main technical decisions and experimental results of testing of laser technological complex are presented. Measurement error in stop-start mode doesnt exceed 2 μm, treatment error under the movement of executive element on the arbitrary contour was no more than 20 μm. The operation speed under the surface microprofiling exceeded 9m/min. The time of continuous work in automatic mode has been more than 15 hours within the temperature range from +18 up to +30 С°.

Laser technological complex, bulk articles laser treatment, cutting, ablation, measurement of 3d objects geometry

Короткий адрес: https://sciup.org/148176166

IDR: 148176166

Статья научная