Features of surgical technique for distal radius fractures management using anatomic volar plating system DVR

Автор: Maximov B.I., Artemiev A.A., Gritsyuk A.A., Ivashkin A.N.

Журнал: Кафедра травматологии и ортопедии @jkto

Статья в выпуске: 1 (31), 2018 года.

Бесплатный доступ

We report our experience of surgical management of 217 patients with distal radius fractures. In all cases we used anatomic volar plating system. In 178 cases (82%) plate osteosynthesis was done via standart volar approach, whereas in 39 cases (18%) - via minimal invasive approach. In general, plate osteosynthesis using this system could be characterised as simple, easy-to-use, comfortable and carefully thought. This made it possible to achieve ideal reduction in 215 cases (99%). The main goal of surgeon in such situation is to decrease complication's rate, especially connected with aggression of surgical approach. This is a reserve for achieving good and excellent results.

Еще

Distal radius fracture, plate osteosynthesis, open reduction, volar approach, minimal invasive approach

Короткий адрес: https://sciup.org/142212810

IDR: 142212810   |   DOI: 10.17238/issn2226-2016.2018.1.34-39

Статья научная