Improvement of corrosion process control techniques at engineering facilities under high parameters of water coolants
Автор: Shcherbakov V.N.
Журнал: Вестник Донского государственного технического университета @vestnik-donstu
Рубрика: Машиностроение и машиноведение
Статья в выпуске: 4 т.18, 2018 года.
Бесплатный доступ
Introduction. The work objective is to increase the reliability of the prediction methods for the lithium hydroxide behavior in the steam-water circuit at the thermal power plants and nuclear power plants, and for the operational monitoring of the pH index of steam solutions. A method of operational control is developed on the basis of the conductometric measurements of the hydrogen index of the corrosion inhibitor vapor solutions for construction materials of lithium hydroxide used at the TPP and NPS.Materials and Methods. A mathematical model method is used for the practical implementation of the high-temperature operational control of the steam solution pH index.Research Results. A method for monitoring the pH of vapor solutions of lithium hydroxide based on the determination of vapor concentration through the steam condensation in the coolable conductivity sensor located in the vapor space of the steam generator is developed. This has significantly improved the accuracy of determining the lithium hydroxide concentration...
Mechanical engineering, corrosion processes, automatic control, vapor phase, conductometric methods, monitoring
Короткий адрес: https://sciup.org/142217055
IDR: 142217055 | DOI: 10.23947/1992-5980-2018-18-4-414-420