A clinical case of repeated correction of Ebstein's anomaly using the 'cone reconstruction' method
Автор: Troshkinev Nikita M., Svyazov Evgenij A., Mochula Olga V., Shmakova Natalia A., Ivanova Inna V., Egunov Oleg A., Krivoshchekov Evgenij V.
Журнал: Патология кровообращения и кардиохирургия @journal-meshalkin
Рубрика: Случаи из клинической практики
Статья в выпуске: 2 т.24, 2020 года.
Бесплатный доступ
We report the case of a 16-year-old child with Ebstein's anomaly who successfully underwent recorrection via the 'cone reconstruction' method using a tricuspid valve-in-ring implant. Because the patient had high-grade atrioventricular block, a pacemaker was implanted. Ultrasound and magnetic resonance imaging were conducted to determine the anatomy of the right ventricle and its hemodynamic parameters. Echocardiography performed at the time of discharge revealed an improvement in the hemodynamic parameters of the patient after the correction: tricuspid valve regurgitation is mild and peak/mean pressure gradient 10/5 mmHg.
Case report, congenital heart disease, cone reconstruction, ebstein's anomaly, repeated surgery
Короткий адрес: https://sciup.org/142230612
IDR: 142230612 | DOI: 10.21688/1681-3472-2020-2-102-108