Control of thyristor keys on primary party transformer with voltage adjustment

Free access

Article is devoted to the analysis of work of thyristor keys on primary party of adding voltage and reducing voltage transformers. The interrelation of corners of switching off of thyristor key and an initial magnetic induction at the moment of their inclusion is shown. Recommendations about a choice of corners of inclusion of the thyristor key which are ensuring functioning of transformers without emissions of a current of magnetisation are made. Charts of currents, voltage and the magnetic induction, illustrating operation of the reducing the voltage transformer are provided. Results of work can be of interest for experts in the field of power electronics and semi-conductor converting equipment.

the transformer with voltage adjustment \ thyristor key \ magnetisation current \ magnetic induction

Similar articles in the section Electrical engineering

Экспериментальный стенд для исследования процессов работы тиристорного и транзисторного выпрямительно-инверторных преобразователей электровоза переменного тока в режиме тяги на первой зоне регулирования
Экспериментальный стенд для исследования процессов работы тиристорного и транзисторного выпрямительно-инверторных преобразователей электровоза переменного тока в режиме тяги на первой зоне регулирования

Власьевский Станислав Васильевич, Мельниченко Олег Валерьевич, Портной Александр Юрьевич, Шрамко Сергей Геннадьевич, Яговкин Дмитрий Андреевич

Short address: https://sciup.org/147158331

IDS: 147158331   |   UDC: 621.314   |   DOI: 10.14529/power150410