Use of mechanical circulatory support in acute circulatory collapse at immediate risk of death after endomyocardial biopsy

Автор: Kavoliunien Aura, Ruzgyt Egl, Jankauskien Loreta

Журнал: Cardiometry @cardiometry

Рубрика: Case report

Статья в выпуске: 3, 2013 года.

Бесплатный доступ

There are various indications for a mechanical circulatory support (MCS) devices implantation. We report a case of the use of the MCS in a 39 year old male with acute circulatory collapse and at immediate risk of death after endomyocardial biopsy in order to keep the patient alive until intrinsic cardiac function recovers sufficiently to remove the MCS. The patient underwent an implantation of the left ventricular assist device according to progressive decline of the cardiac function due to a heart muscle disease. With successful regression of heart failure symptoms and reverse remodeling of LV, the device was explanted after four month. Evidence of myocardial reverse remodeling and functional improvement during MCS in our patient proved the use of mechanical ventricular unloading as a therapeutic strategy aimed at cardiac recovery, allowing removal of the MCS device instead of extending his use as a bridge to heart transplantation.

Еще

Circulatory collapse, endomyocardial biopsy, mechanical circulatory support

Короткий адрес: https://sciup.org/148308748

ID: 148308748

Список литературы Use of mechanical circulatory support in acute circulatory collapse at immediate risk of death after endomyocardial biopsy

  • Peura JL, Colvin-Adams M, Francis GS et al. Recommendations for the use of mechanical circulatory support: device strategies and patient selection. A scientific statement from the American Heart Association. Circ 2012; 126:2648-2667.
  • Cooper LT, Baughman KL, Feldman AM et al. The role of endomyocardial biopsy in the management of cardiovascular disease. ESC clinical practice guidelines. Eur Heart J 2007;28:3076-3093.
  • Stevenson LW, Pagani FD, Young JB et al. INTERMACS Profiles of Advanced Heart Failure: The Current Picture J Heart Lung Transplant 2009; 28:535-41.
  • Holzmann M, Nicko A, Kühl U et al. Complication rate of right ventricular endomyocardial biopsy via the femoral approach. A scientific statement from the American Heart Association. Circ 2008; 118:1722-1728.
  • Parissis H, Soo A, Al-Alao B. Intra-aortic balloon pump (ΙΑΒΡ): from the old trends and studies to the current “extended” indications of its use. J of Cardiothoracic Surg 2012; 7:128.
  • Krabatsch T, Schweiger M, Dandel M et al. Is bridge to recovery more likely with pulsatile left ventricular assist devices than with nonpulsatile-flow systems? Ann Thorac Surg 2011; 91:1335-1340.
  • Dandel M, Weng Y, Siniawski H et al. Heart failure reversal by ventricular unloading in patients with chronic cardiomyopathy: criteria for weaning from ventricular assist devices. Eur Heart J 2011; 32(9):1148-1160.
Еще
Отчет