Assessment of straw construction technologies in terms of thermal efficiency

Автор: Aznabaev Askar Azamatovich, Ovsyannikova Alla Valeryevna, Povzun Anastasiia Olegovna, Gaevskaya Zlata Anatolyevna

Журнал: Строительство уникальных зданий и сооружений @unistroy

Статья в выпуске: 4 (43), 2016 года.

Бесплатный доступ

Sustainable construction nowadays requires the use of environmental friendly materials with high rate of insulation. Straw construction presents some advantages such as renewability with low energy input, recyclability, CO2 storage, and local availability that implies short distribution cycle. However, before the introduction in the construction industry, attention needs to be paid to the construction technology using such natural materials. In this paper there were developed elements of enclosing structures for two technologies of straw frame building; was done thermal modeling of potentially weak assembles of building envelope; were calculated R-values and then compared with normative indexes; was evaluated efficiency of usability two technologies of low-raise building in cold and wet conditions of St. Petersburg.

Еще

Короткий адрес: https://sciup.org/14322427

IDR: 14322427

Список литературы Assessment of straw construction technologies in terms of thermal efficiency

  • Hozman O. Environment, health and aesthetics of building. Green building. 2012. No.1. pp. 58-61.
  • Jones B. Building with straw bales. Totnes. Green Books. 2002. 125 p.
  • King B. Design of straw bale buildings. San Rafael. Green Building Press. 2006. 259 p.
  • Steen A-S., Steen B., Bainbridge D. The straw bale house. White River Junction. Chelsea Green Publishing Co. 1994. 297 p.
  • Milutiene E., Jurmann K., Keller L. Straw bale building -reaching energy efficiency and sustainability in Northern Latitudes. Earthzine. Published on Monday. 2010. pp. 1-6.
  • Lawrence M., Heath A., Walker P. Determining moisture levels in straw bale construction. Construction and Building Materials. Elsevier. 2009. No. 23. pp. 2763-2768.
  • Drive P. ASTM E119-05a Fire tests of building construction and materials: 1 Hr fire resistance test of a nonloadbearing straw bale wall. San Rafael. CA. 2006. 50 p.
  • Box P. ASTM E119-05a fire tests of building construction and materials: 2 Hr fire resistance test of a nonloadbearing straw bale wall. (2006) Tucson. AZ. 2006. 53 p.
  • Zhou H., Jensen A.D., Glarborg P., Jensen P.A., Kavaliauskas A. Numerical modeling of straw combustion in a fixed bed. Fuel. 2005. No. 84. pp. 389-403.
  • Wooley T. Natural building. Crowood Press. Marlborough. 2006. 282 p.
  • Grandsaert M. Compression test of plastered straw-bale walls. Proceedings of the first international conference on ecological building structure. San Rafael. 2001. pp. 43-44.
  • Bou-Ali G. Compressive and lateral loading of straw bale walls. MSc dissertation. University of Tucson, Arizona. 1993.
  • Nichols J., Raap S. Straw bale shear wall lateral load test. Proceedings of the first international conference on ecological building structure. San Rafael. 2001. p. 24.
  • Ash C., Aschheim M., Mar D. In plane cyclic tests of plastered straw bale wall assemblies. University of Illinois. 2003. 31 p.
  • Watts K., Wilkie K., Thompson K., Corson J. Thermal and mechanical properties of straw bales as they relate to a straw house. Can Soc Agr Eng. 1995. pp. 95-209.
  • Faine M., Zhang J. A pilot study examining the strength and serviceability of rendered straw bale walls. Proceedings of the first international conference on ecological building structure. San Rafael. 2001. p. 14.
  • Faine M., Zhang J. A pilot study examining and comparing the load bearing capacity and behavior of an earth rendered straw bale wall. International straw bale building conference. Wagga. 2002. p. 19.
  • Walker P. Compression load testing of straw bale walls. Technical report. University of Bath. 2004. 29 p.
  • Stone N. Thermal Performance of Straw Bale Wall Systems. Ecological Building Network. 2003. pp. 1-7.
  • Carfrae J., De Wilde P., Littlewood J., Goodhew S., Walker P. Development of a cost effective probe for the long term monitoring of straw bale buildings. Building and Environment. 2011. No. 46. pp. 156-164.
  • Ashour T., Georg H., Wu W. An experimental investigation on equilibrium moisture content of earth plaster with natural reinforcement fibres for straw bale buildings. Applied Thermal Engineering. 2011. No. 31. pp. 293-303.
  • Kierulf B. EcoCocon, Passivhaus Manual. 2014. 63 p.
  • Brossamain V. Build your house of straw according to G.R.E.B technique. Edition V. Brossamain. 2006.
  • Sertifikat na ispolzovaniye programmnogo produkta WINDOW-TEST (THERM) pri raschetakh konstruktsiy po GOST 26601.1. Assotsiatsiya proizvoditeley okonnykh konstruktsiy APROK-Test . URL: http://www.aprok.org/aprok-test.php (rus)
  • SP 50.13330.2012 Teplovaya zashchita zdaniy. Moskva, Rossiya. 2013. (rus)
  • RMD 23-16-2012 Rekomendatsii po obespecheniyu energeticheskoy effektivnosti zhilykh i obshchestvennykh zdaniy dlya g. Sankt-Peterburg. OAO KB vysotnykh i podzemnykh sooruzheniy. Sankt-Peterburg, Rossiya. 2013.
  • Aznabaev A.A., Ovsyannikova A.V., Povzun A.O., Gaevskaya Z.A Assessment of straw construction technologies in terms of thermal efficiency of enclosing structures/Азнабаев А.А., Овсянникова А.В., Повзун А.О., Гаевская З.А. Оценка применения технологий соломенного строительства с точки зрения тепловой эффективности ограждающих конструкций ©
  • GOST R ISO 7730-2009 Ergonomika termalnoy sredy -analiticheskoye opredeleniye i interpretatsiya komfortnosti teplovogo rezhima s ispolzovaniyem pokazateley PMV i PPD i kriteriyev lokalnogo teplovogo komforta. NITs KD. Moskva, Rossiya. 2010. (rus)
  • Kornienko S.V. Method of Three-Dimensional Simultaneous Non Standard Problem Solution with Heat and Moisture Transfer for Enclosing Structures of Buildings. News of higher educational institutions. Construction. 2006. No. 2. pp. 108-110. (rus)
  • Kornienko S.V. Engineering assessment of humidity on external walls. Internet-Vestnik VolgGASU. 2015. No.1 (37). p. 19. (rus)
Еще
Статья научная