Study of PET Fiber Concrete in Beam-Column Joint under Cyclic Loading Using Finite Element Analysis

Автор: Nirav M. Patel, M.N. Patel, Tapsi D. Sata

Журнал: International Journal of Engineering and Manufacturing @ijem

Статья в выпуске: 5 vol.13, 2023 года.

Бесплатный доступ

The failure behavior of beam-to-column connections can be minimized or avoided to some extent by using PET waste fibers. With the change of composition, different seismic performances of concrete joints can be adjusted. FEM analysis was performed in ABAQUS software to compare the performance of concrete beam-to-column connections reinforced with conventional concrete fibers and waste PET under cyclic loading. The concrete mix is designed to achieve a concrete grade of M25. Seven figures of the external beam-to-column connections were modeled as a quarter of the architectural prototype. The first joint is conventional concrete and designed according to IS 1893 (Part 1):2022 and the reinforcement in the joint part are specified according to the ductility requirements of IS 13920:2016. Six other samples were designed to contain different PET waste fibers (0.25% to 1.50%) in the seam area. Beam-to-column connections have 0.75% to 1.25% PET fiber inclusions that have better performance in terms of strength, load-carrying capacity, energy dissipation capacity, joint shear strength, and ductility in the joint area. Incorporating PET waste fibers into concrete can provide the best solution for waste management, and also has the potential to reduce the cost of reinforced concrete by 15%-20% holds economic significance, and concrete with PET waste fibers indeed demonstrates better seismic performance, and could lead to increased safety and longevity of structures in seismic-prone areas. This suggests that experimental work or studies might have explored how these fibers affect the concrete's properties, strength, durability, and other characteristics.

Еще

Strength performance, PET waste fiber, Failure behavior, Exterior beam-column, Waste management

Короткий адрес: https://sciup.org/15018712

IDR: 15018712   |   DOI: 10.5815/ijem.2023.05.05

Список литературы Study of PET Fiber Concrete in Beam-Column Joint under Cyclic Loading Using Finite Element Analysis

  • Pacheco-Torgal, F.: Introduction to the use of recycled plastics in eco-efficient concrete. In: Use of Recycled Plastics in Eco-Efficient Concrete, pp. 1–8. Elsevier, Amsterdam (2019).
  • Whinfield, John Rex and Dickson, James Tennant (1941) "Improvements Relating to the Manufacture of Highly Polymeric Substances", UK Patent 578,079; "Polymeric Linear Terephthalic Esters", U.S. Patent 2,465,319 Publication date: 22 March 1949.
  • Bhogayata, A., Arora, N.K.: Green concrete from the post-consumer plastic wastes: Indian scenario, pp. 437–440 (2011).
  • Jain, A., et al.: Fresh, strength, durability and microstructural properties of shredded waste plastic concrete. Iran. J. Sci. Technol. Trans. Civ. Eng. 43(1), 455–465 (2019).
  • E. Rahmani, M. Dehestani, M.H. Beygi, H. Allahyari, I.M. Nikbin, On the mechanical properties of concrete containing waste PET particles, Constr. Build. Mater. 47 (2013) 1302–1308.
  • Nirav M. Patel, M. N. Patel: Behavioral Changes in Strength of Concrete Reinforced by Waste Plastic Fibers. Information and Communication Technology for Competitive Strategies (ICTCS 2020). Volume 191, 431 – 439. Springer, Singapore. https://doi.org/10.1007/978-981-16-0739- 4_41.
  • S. Yang, X. Yue, X. Liu, Y. Tong, Properties of self-compacting lightweight concrete containing recycled plastic particles, Constr. Build. Mater. 84 (2015) 444–453.
  • D. Foti, Use of recycled waste pet bottles fibers for the reinforcement of concrete, Compos. Struct. 96 (2013) 396–404.
  • D. Foti, Preliminary analysis of concrete reinforced with waste bottles PET fibers, Constr. Build. Mater. 25 (4) (2011) 1906–1915.
  • Nirav M. Patel, Dr. M. N. Patel. (2021). Strength Performance of Concrete by using Polyethylene-Terephthalate Waste Fibers as Concrete Constitute. Design Engineering, 141 - 156.
  • Paul R. Gefken and Melvin, R. Rame. Increased joint hoop spacing in Type 2 seismic joints using fibre reinforced concrete, ACI Structural Journal, No. 2, 86(1989) 168-72.
  • Filatrault A, Ladicani K, and Massicotte B. Seismic performance of code designed fibre reinforced concrete joints, ACI Structural Journal, No. 5, 91(1994) 564-71.
  • Filiatrault A, Pineau S, and Houde J. Seismic behaviour of steel fibre reinforced concrete interior beam-column joints, ACI Structural Journal, No. 5, 92(1995) 543-51.
  • Thanukumari B, Perumal P. Behaviour of Fibre Reinforced Exterior Beam Column Joint Subjected to Cyclic Load, Proceedings of the National Conference on Advances in Construction Materials, Methods and Management (AC3M-’09) at Chaitanya Bharathi Institute of Technology, Hydrabad, (2009) pp. 429-436.
  • Indian Standard Plain and Reinforced Concrete Code of Practice, IS 456:2000 Bureau of Indian Standards, New Delhi, 2000.
  • Indian Standard Criteria for Earthquake resistant Design of Structures, Part I General Provisions and Building IS 1893 (Part I) 2002 Bureau of Indian Standards, New Delhi, 2002.
  • Ganganagoudar, A., Mondal, T. G., and Suriya Prakash, S. (2016). Analytical and finite element studies on behavior of FRP strengthened RC beams under torsion. Composite Structures, 153, 876-885. https://doi.org/10.1016/j.compstruct.2016.07.014.
  • Belarbi A. and Hsu T.T.C. (1994). Constitutive laws of concrete in tension and reinforcing bars stiffened by concrete, ACI Struct J, 91(4), 465-74.
  • Murty, C. V. R., Durgesh C. Rai, Bajpai, K. K. and Jain, K. ‘Effectiveness of Reinforcement Details in Exterior Reinforced Concrete Beam-Column Joints for Earthquake Resistance”, ACI Structural Journal, Vol. 100, No. 2, pp. 149-156, 2003.
  • Ganesan, N. and Indira, P.V. “Latex modified SFRC beam-column joints subjected to cyclic loading”, The Indian Concrete Journal, July pp. 416-420, 2000.
Еще
Статья научная